Heating not working but hot water is fine? If your shower has hot water but your floor heating isn’t working, the problem may be related to the heating settings rather than a complete boiler failure. Manufacturer manuals list heating checks that are separate from hot water: heating mode, set temperature, Away and Timer functions, and room controls. Start with those. Anything involving filters, air in the pipes, or frozen pipes is a job for a technician.
These checks are based on specific Navien and Rinnai models; controls vary by model. Check the manual for your own boiler.
Safety first: If you smell gas, do not operate electrical switches or appliances. Leave the area and call 119 or your gas supplier from a safe location.
Here’s a quick overview of what to check, based on what you’re noticing right now:
| What you notice | Check first | Who handles it |
|---|---|---|
| The whole home is cold, panel looks normal | Heating mode and set temperature | You |
| Heating only works at certain hours | Timer or Away setting | You |
| Only one room is cold | That room’s controller and valve status | You, then the management office |
| Still cold after the settings are right | Filter, air in the pipes, frozen pipes | Technician |
Whole Home Cold or Just One Room?
Figure out the pattern before you touch anything. It changes where you start.
If every room is cold, start with Steps 1 and 2: mode, temperature, Timer and Away. If only one room is cold, go to Step 3 first. A single cold room points toward that room’s controller or valve, but the manuals do not rank causes, so check each step in order.
Step 1: Check the Heating Mode and Temperature
- Make sure heating is on and the mode is not hot-water-only. Navien’s NCB311 manual (page 25, ‘heating does not work’) says to switch from hot-water-only or heating-off to indoor heating (실내난방) or ondol heating (온돌난방). Rinnai’s R322(N) user manual (pre-service checklist) says to turn the heating function on.
- Both manuals say to raise the set temperature if it is too low.
- Both note that heating may not run while hot water is in use. Wait until the tap is closed and check again.
Mode names differ by model. For what each button does, see our Korean Ondol Floor Heating guide.
Step 2: Check Away and Timer Settings
- Navien lists a long Timer interval (예약) as a cause. Shorten the interval or adjust the schedule.
- Rinnai says to cancel Away (외출) and Timer functions if the room is not heating.
A schedule set weeks ago can quietly block heating today, so check it even if you don’t remember setting one.
Step 3: Check Individual Room Heating
If only one room stays cold, check that room’s controller and valve first. These are possible causes, not a confirmed diagnosis.
- Rinnai lists the room controller (각방제어기): check each room’s heating setting. A simple way to do this is to compare the cold room’s controller with a warm room’s: is the mode the same, and is the set temperature higher than the room’s current temperature?
- Both manuals list the room valve (각방밸브): a closed valve means that room gets no heat.
- If the controller looks correct but that room is still cold, the valve is the next thing to ask about.
If you cannot identify the correct room valve or are unsure how to access it safely, contact your landlord or building management office.
If the Settings Are Right but the Floor Is Still Cold
Don’t start taking things apart yet. Go back through the mode, the set temperature, Timer and Away once more, and make sure no hot water is running.
If everything is correct and the floor is still cold, stop adjusting settings. The remaining items in the manuals are not settings, so they belong in Step 4 and Step 5. Before you contact anyone:
- Take a photo of the panel showing the mode, the set temperature and any code.
- Note which rooms are cold and when it started.
- Write down what you already checked, so you don’t repeat it on the phone.
- Do not open the boiler or work on the pipes yourself.
Step 4: Possible Circulation Problems (Leave These to a Technician)
Navien’s manual lists a clogged heating filter, air in the heating pipes, and frozen heating pipes. Rinnai lists the filter and air in the pipes. The manuals give model-specific steps, but here’s what matters for renters.
- Do not take apart a filter or bleed air unless your own model’s manual says you may.
- During freezing weather, Kiturami warns that a lack of heating may be caused by frozen boiler components or heating pipes, and tells you to contact its service center. See Frozen Pipes in Korea: No Water or Heat? What to Do, and Preventing Frozen Pipes in Korea for cold-weather habits.
- If the panel shows an error code, see our Korean Boiler Error Codes guide.
Step 5: When to Call for Service
If the heating is still not working after the safe checks in Steps 1 to 3, contact your landlord, building management office, or a qualified technician. Do not attempt internal boiler or pipe repairs yourself. Having a few details ready also makes the call shorter.
- Renters: contact the landlord or management office first.
- Manufacturer lines: see the table below. Check the label on your boiler for the brand.
- Overheating, unusual noise, or vibration: stop using the boiler, turn off the power, and have a professional inspect it (Ministry of the Interior and Safety guidance).
| Brand | Customer center |
|---|---|
| Kiturami | 1588-9000 |
| Navien | 1588-1144 (24 hours, every day) |
| Rinnai | 1544-3651 |
Have this ready before you call: the boiler model name (on the label), what the panel shows (mode, set temperature, any code), whether the whole home or only some rooms are cold, when it started, and what you already checked.
If hot water works but heating doesn’t, these Korean phrases help when you’re speaking with building staff or a technician in person:
| English | Korean |
|---|---|
| Hot water works, but heating doesn’t. The floor is cold. | 온수는 나오는데 난방이 안 돼요. 방바닥이 차가워요. |
| Only this room is cold. | 이 방만 따뜻하지 않아요. |
| I checked the heating settings, but it is still cold. | 난방 설정은 확인했는데도 차가워요. |
| The boiler model is … | 보일러 모델명은 …예요. |
Related guides: Boiler Won’t Turn On in Korea, and No Hot Water in a Korean Apartment.
If You Smell Gas, This Is a Different Situation
Gas smell changes everything. Stop troubleshooting the heating and move straight to safety steps.
- Do not touch electrical switches, plugs, or appliances, and keep flames away.
- If it is safe, close the gas valve (for city gas, the valve on the meter).
- Open windows and doors to ventilate. Do not turn on a fan or ventilator.
- Leave the area, then contact your gas supplier or call 119.
- Have the gas supplier inspect before you use gas again.
Sources and References
- Navien NCB311 user manual, page 25, ‘Heating does not work’
- Rinnai R322(N) user manual, pre-service checklist
- Kiturami, January 3, 2020 (frozen parts as a cause of no heating)
- Ministry of the Interior and Safety via Korea Policy Briefing (December 30, 2022)
- Korea Gas Safety Corporation, gas leak safety rules
- Navien customer center
This guide was compiled on November 3, 2026 from the pages listed above under Sources and References. These checks are based on specific Navien and Rinnai models, so controls vary by model.